Hella 4RA 933.332-181 Std 5 Blade 12 Volt 20/40 Amp Dual Circuit Relay For Fans, Ignition Or Lights
Estimate Shipping
Price: $11.99
39 In Stock
Sold As:
1 Relay
Part Number: HEL933332181
MFG Number:
4RA 933.332-181
California Prop 65 Warning: This item may cause cancer or reproductive harm. For more info visit p65warnings.ca.gov
Description
Important Note: Always stop and look at the relay to note the positions of each number on each blade ! ! For example Hella's black 40 amp relays have their #30 constant power in a different position than the Hella blue fused relays, but the plug or box will fit either of those relays.
Hella's universal 5 prong relays. Typically used for:
If you're using this as a headlight relay, to figure out the amount of amps your lights are using, use the total wattage of your lights and divide that by the volts. For instance if your lights are 100w each then 100w ÷ 12v = 8.33a. So if you had four 100w lights using 33.33 amps and your toggle switch is only rated at 10 amp then you could use that 10 amp toggle switch to activate this 40 amp relay and be covered for the 33.33 amps of lights that you're running.
Hella's universal 5 prong relays. Typically used for:
- Hard start relay to get the amp load off of your ignition switch
- Headlight relay to run a low amp toggle switch with lights that draw up to 40 amps
- Fan relay to take away the amp draw from the ECU or thermostat to your radiator fans
- Fuel pump relay
If you're using this as a headlight relay, to figure out the amount of amps your lights are using, use the total wattage of your lights and divide that by the volts. For instance if your lights are 100w each then 100w ÷ 12v = 8.33a. So if you had four 100w lights using 33.33 amps and your toggle switch is only rated at 10 amp then you could use that 10 amp toggle switch to activate this 40 amp relay and be covered for the 33.33 amps of lights that you're running.
- #86 wire is switched power on. The trigger wire from a toggle switch or thermostat
- #87 wire goes to your lights, starter solenoid, fuel pump, or radiator fans. This is a 40 amp circuit
- #87a wire is normally not used. When the toggle switch is turned OFF to 86 the 87a then becomes ON. This is a 20 amp circuit
- #30 wire is for 12v constant power. Obviously run a fuse or circuit breaker on this wire
- #85 is a ground wire